Limit the number of leader points
■
Constrain the angle of the first and second leader segments
If associative dimensioning is turned on with DIMASSOC, the leader start
point can be associated with a location on an object. If the object is relocated,
the arrowhead remains attached to the object and the leader line stretches,
but the text or feature control frame remains in place.
Specify First Leader Point, or [Settings] <Settings>: Specify the first leader point, or
press ENTER to specify leader settings
First Leader Point
Specify next point: Specify the next leader point
Specify next point: Specify the next leader point, or press ENTER to specify the
leader annotation
The Number of Points setting on the Leader Line & Arrow tab of the Leader
Settings Dialog Box determines the number of leader points you are prompted
to specify.
The prompt that is displayed next depends on settings selected on the
Annotation tab in the Leader Settings dialog box.
If Mtext and Prompt for Width are selected on the Annotation tab, the
following prompts are displayed:
Specify the width <current>: Specify the multiline text width by creating a text
boundary or entering a value
If you set the text width value to 0.00, the width of the multiline text is
unlimited.
Enter first line of annotation text: Enter the first line of text
Press ENTER once to enter another line of text, or press ENTER again to
complete the command.
If Copy an Object is selected on the Annotation tab, the following prompt is
displayed:
Select an object to copy: Select a text object, block reference, or tolerance object
(feature control frame)
The object is attached to the leader.
If Tolerance is selected on the Annotation tab, the Geometric Tolerance Dialog
Box is displayed. Use the dialog box to create the tolerance feature control
frame. When you choose OK, the feature control frame is attached o the leader.
If Block Reference is selected on the Annotation tab, the following prompts
are displayed:
| 939
Содержание AUTOCAD 2006
Страница 1: ...February 2005 AutoCAD 2006 Command Reference ...
Страница 24: ......
Страница 30: ...6 ...
Страница 212: ...188 ...
Страница 448: ...424 ...
Страница 554: ...530 ...
Страница 584: ...560 ...
Страница 588: ...564 ...
Страница 660: ...636 ...
Страница 750: ...726 ...
Страница 760: ...736 ...
Страница 889: ...You can display more options in the Plot dialog box by clicking the More Options button Plot Dialog Box 865 ...
Страница 960: ...936 ...
Страница 1194: ...1170 ...
Страница 1244: ...Undo Reverses the most recent change made by TRIM 1220 Chapter 21 ...
Страница 1310: ...1286 ...
Страница 1328: ...1304 ...
Страница 1354: ...Zoom Window Zooms to display an area specified by a rectangular window 1330 Chapter 26 ...
Страница 1490: ......