6-2: System Parameters
ini File Field Name
Web Parameter Name
Valid Range and Description
FarEndDisconnectSilenc
eMethod
For a description of this parameter, refer to 'General Parameters' on
page
100
.
FarEndDisconnectSilenc
eThreshold
Threshold of the packet count (in percents), below which is considered
silence by the gateway.
The valid range is 1 to 100. The default is 8%.
Note:
Applicable only if silence is detected according to packet count
(FarEndDisconnectSilenceMethod = 1).
Automatic Update Parameters
CmpFileURL
Specifies the name of the
cmp
file and the location of the server (IP
address or FQDN) from which the gateway loads a new
cmp
file and
updates itself. The
cmp
file can be loaded using: HTTP, HTTPS, FTP,
FTPS or NFS.
For example: http://192.168.0.1/filename
Notes:
When this parameter is set in the
ini
file, the gateway always loads
the
cmp
file after it is reset.
The
cmp
file is validated before it's burned to flash. The checksum of
the
cmp
file is also compared to the previously-burnt checksum to
avoid unnecessary resets.
The maximum length of the URL address is 99 characters.
IniFileURL
Specifies the name of the
ini
file and the location of the server (IP
address or FQDN) from which the gateway loads the
ini
file. The
ini
file
can be loaded using: HTTP, HTTPS, FTP, FTPS or NFS.
For example:
http://192.168.0.1/filename
http://192.8.77.13/config<MAC>
https://<username>:<password>@<IP address>/<file name>
Notes:
When using HTTP or HTTPS, the date and time of the
ini
file are
validated. Only more recently-dated
ini
files are loaded.
The optional string '<MAC>' is replaced with the gateway's MAC
address. Therefore, the gateway requests an
ini
file name that
contains its MAC address. This option enables loading different
configurations for specific gateways.
The maximum length of the URL address is 99 characters.
PrtFileURL
Specifies the name of the Prerecorded Tones file and the location of the
server (IP address or FQDN) from which it is loaded.
For example: http://server_name/file, https://server_name/file.
Note:
The maximum length of the URL address is 99 characters.
CptFileURL
Specifies the name of the CPT file and the location of the server (IP
address or FQDN) from which it is loaded.
For example: http://server_name/file, https://server_name/file.
Note:
The maximum length of the URL address is 99 characters.
Содержание Mediapack mp-11x
Страница 1: ...Document LTRT 65409 August 2007 User s Manual Version 5 2...
Страница 2: ......
Страница 14: ...SIP User s Manual 14 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 18: ...SIP User s Manual 18 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 22: ...SIP User s Manual 22 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 44: ...SIP User s Manual 44 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 47: ...Version 5 2 47 August 2007 SIP User s Manual 4 Getting Started Figure 4 1 Startup Process...
Страница 322: ...SIP User s Manual 322 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 380: ...SIP User s Manual 380 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 388: ...SIP User s Manual 388 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 390: ...User s Manual Version 5 2 www audiocodes com...