Version 5.2
107
August 2007
SIP User's Manual
5. Web-based Management
Table
5-12: General Parameters (Advanced Parameters)
Parameter
Description
Delay After Reset [sec]
[GWAppDelayTime]
Defines the amount of time (in seconds) the gateway's operation is
delayed after a reset cycle.
The valid range is 0 to 45. The default value is 7 seconds.
Note:
This feature helps to overcome connection problems caused by
some LAN routers or IP configuration parameters change by a DHCP
Server.
Max Number of Active
Calls
[MaxActiveCalls]
Defines the maximum number of simultaneous active calls supported by
the gateway. If the maximum number of calls is reached, new calls are
not established.
The default value is max available channels (no restriction on the
maximum number of calls). The valid range is 1 to max number of
channels.
Max Call Duration (min)
[MaxCallDuration]
Defines the maximum call duration in minutes. If this time expires, both
sides of the call are released (IP and Tel).
The valid range is 0 to 35791. The default is 0 (i.e., no limitation).
Enable LAN Watchdog
[EnableLanWatchDog]
[0]
Disable = Disable LAN Watch-Dog (default).
[1]
Enable = Enable LAN Watch-Dog.
When LAN Watch-Dog is enabled, the gateway's overall communication
integrity is checked periodically. If no communication for about 3 minutes
is detected, the gateway performs a self test.
If the self test succeeds, the problem is logical link down (i.e., Ethernet
cable disconnected on the switch side), and the Busy Out mechanism is
activated if enabled (EnableBusyOut = 1). Lifeline is activated if enabled.
If the self test fails, the gateway restarts to overcome internal fatal
communication error.
Note
1
:
Enable LAN Watchdog is relevant only if the Ethernet
connection is full duplex.
Note 2: LAN Watchdog is not applicable to MP-118.
Enable Calls Cut Through
[CutThrough]
Enables users to receive incoming IP calls while the port is in an offhook
state.
[0]
Disable = Disabled (default).
[1]
Enable = Enabled.
If enabled, FXS gateways answer the call and 'cut through' the voice
channel, if there is no other active call on that port, even if the port is in
offhook state.
When the call is terminated (by the remote party), the gateway plays a
reorder tone for TimeForReorderTone seconds and is then ready to
answer the next incoming call, without onhooking the phone.
The waiting call is automatically answered by the gateway when the
current call is terminated (EnableCallWaiting = 1).
Note:
This option is applicable only to FXS gateways.
Enable User-Information
Usage
[EnableUserInfoUsage]
Enables or disables usage of the User Information loaded to the gateway
via the User Information auxiliary file.
[0]
Disable = Disabled (default).
[1]
Enable = Enabled.
Содержание Mediapack mp-11x
Страница 1: ...Document LTRT 65409 August 2007 User s Manual Version 5 2...
Страница 2: ......
Страница 14: ...SIP User s Manual 14 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 18: ...SIP User s Manual 18 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 22: ...SIP User s Manual 22 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 44: ...SIP User s Manual 44 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 47: ...Version 5 2 47 August 2007 SIP User s Manual 4 Getting Started Figure 4 1 Startup Process...
Страница 322: ...SIP User s Manual 322 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 380: ...SIP User s Manual 380 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 388: ...SIP User s Manual 388 Document LTRT 65409 MediaPack Series Reader s Notes...
Страница 390: ...User s Manual Version 5 2 www audiocodes com...