I/O banks between two DLLs have the flexibility to create multiple frequencies and multiple-type interfaces.
These banks can use settings from either or both adjacent DLLs. For example,
DQS1R
can get its phase-shift
settings from
DLL_TR
, while DQS2R can get its phase-shift settings from
DLL_BR
.
The reference clock for each DLL may come from the PLL output clocks or clock input pins.
If you have a dedicated PLL that only generates the DLL input reference clock, set the PLL mode to
Direct Compensation to achieve better performance (or the Quartus II software automatically
Note:
changes it). Because the PLL does not use any other outputs, it does not have to compensate for any
clock paths.
DLL Reference Clock Input for Cyclone V Devices
Table 6-11: DLL Reference Clock Input from PLLs for Cyclone V E (A2, A4, A5, A7, and A9), GX (C4, C5, C7, and
C9), and GT (D5, D7, and D9) Devices—Preliminary
PLL
DLL
Bottom Right
Bottom Left
Top Right
Top Left
—
—
—
pllout
DLL_TL
—
—
pllout
—
DLL_TR
—
pllout
—
—
DLL_BL
pllout
—
—
—
DLL_BR
Table 6-12: DLL Reference Clock Input from PLLs for Cyclone V GX (C3) Device—Preliminary
PLL
DLL
Bottom Right
Bottom Left
Top Right
Top Left
—
—
—
pllout
DLL_TL
—
—
pllout
—
DLL_TR
—
—
—
—
DLL_BL
pllout
—
—
—
DLL_BR
Table 6-13: DLL Reference Clock Input from PLLs for Cyclone V SE A2, A4, A5, and A6 Devices, Cyclone V SX
C2, C4, C5, and C6 Devices, and Cyclone V ST D5 and D6 Devices—Preliminary
PLL
DLL
Bottom Right
Bottom Left
Top Right
Top Left
—
—
—
pllout
DLL_TL
—
—
—
—
DLL_TR
—
pllout
—
—
DLL_BL
Altera Corporation
External Memory Interfaces in Cyclone V Devices
6-19
DLL Reference Clock Input for Cyclone V Devices
CV-52006