Troubleshooting
52. CD Models: No Start With Vend Satisfied and Start Button Pushed
240 Volt/60 Hertz/1 Phase Gas Nonreversing
NOTE: All voltage checks are referenced to neutral unless stated otherwise.
NOTE: If motor only runs with start switch pressed in, that means centrifugal switch in motor is bad.
Replace motor.
CD Models: No start with
vend satisfied and start
button pushed
Is there
voltage to
the N.C. terminal
of switch A?
TMB2179S-a
Correct wiring
between L1
on TBI and
switch A.
No
Is there
voltage to
COM terminal of
switch A?
Check for proper
operation of
switch A. Replace
switch A if
necessary.
Is there
voltage to COM
terminal of the
door switch?
Correct wiring
between door
switch and switch
A of the rotary
coin drop.
With the door
closed, is there voltage
to the N.O. terminal
of the door
switch?
Check door
switch for
proper
operation,
replace if
necessary.
Is there
voltage across
the coil of the
control relay
(CR)?
Correct wiring
to the control
relay.
Is there
voltage to terminal 5
of the motor?
Correct wiring
between
motor and
door switch.
Is there
voltage to the
input side of the
start switch?
Correct wiring
between start
switch and
door switch.
With the
start button pressed in,
is there voltage to the
output side of the start
button?
Replace start
switch.
Yes
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
Yes
Yes
Continued on
next page
Yes