Troubleshooting
33. Igniter Sparks, No Main Burner Ignition – Instant Electronic Ignition
Igniter sparks, no
main burner ignition –
Instant Electronic Ignition
Is igniter
sparking?
Is green wire
from IEI control
connected to
ground terminal?
Yes
Check gas valve coils and
replace as required.
Connect green
wire to ground
terminal.
No
TMB2160S
Is gas
shut-off valve
turned on?
Yes
Open gas
shut-off valve.
No
Is 120 volts
present on black
wire from IEI
control?
Replace IEI
control.
Is IEI control in
safety lockout reset
by opening and
closing door?
Open and
close door.
No
Yes
Yes
Yes
No
Is resistance of
high voltage lead
greater than 25,0000
ohms or less than
5,000 ohms?
Replace high
voltage lead.
Is
igniter gap not
5/32 inch (.397 cm)
or is ceramic
cracked?
Re-gap or
replace igniter.
Replace IEI
control.
No
Yes
No
Yes
No