7. Pilot Goes Out – Standing Pilot Ignition Gas Models
Pilot goes out -
Standing Pilot Ignition
Gas Models
Is exhaust
system
improper or
inadequate?
Refer to
Installation
Manual
for
exhaust system
requirements.
Is lint screen
clogged?
Remove and
clean lint
screen.
Is burner
flame
Improperly
adjusted?
Close air shutter
slightly - A harsh
roaring flame will
draw pilot flame out.
Is there
carbon
accumulation
on heated end
of pilot
thermocouple?
Wipe carbon
off end of
thermocouple.
Yes
Yes
No
Yes
No
Yes
TMB2136S
No
Is pilot orifice
incorrect?
Tumbler is
equipped for
type of gas
specified on
serial plate. If
pilot orifice is
different from
that specified
on serial plate,
obtain and
install correct
orifice.
Check and
replace reset
assembly or
thermocouple
if necessary.
Is gas
valve reset
assembly or
thermocouple
inoperative?