60
70410501
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
41. MM Models: Cylinder Motor Does Not Run or Reverse With Door Closed,
Cycle Selected and Start Button Pressed In Reversing Mode or
Nonreversing Mode (continued)
480 Volt/60 Hertz/3 Phase Steam Reversing and 208-240 Volt/60 Hertz/3 Phase Gas and Steam
Reversing Models
NOTE: If the unit will not reverse when reversing is selected, check for proper operation and wiring of
reversing switch. Replace if necessary.
Is there
voltage to L1, L2, L3 on
the forward contactor or
voltage to terminals X, Y
and Z on the reversing
contactor?
TMB2168S-b
Is
there voltage
to L1, L2 and L3 at
the cylinder
motor?
Unit
operational.
Is there voltage
at the CW or CCW
terminal on the solid
state timer?
Correct wiring
between the
solid state timer
and either the
forward or
reversing coil.
Is there voltage
at L1 of the solid
state timer?
Replace solid
state timer.
Yes
No
Yes
Continued from
previous page
Is there
voltage across the
coils of either the
forward or
reversing
contactor?
Replace either
the forward or
reversing
contactor.
Correct wiring between
cylinder motor and
forward or reversing
contactor.
Yes
No
Yes
No
Yes
No
Is there voltage
to the output of the
auxiliary contacts on the
motor contactor?
Correct wiring
between motor
contactor and
solid state timer.
No
Yes
Is there voltage
to the input side of the
auxiliary contacts on the
motor contactor?
Replace motor
contactor.
Correct wiring
between motor
contactor and
TB1-L1 supply.
No
Yes
No