Troubleshooting
12. Burner Ignites and Goes Out Repeatedly – Glow-Bar Ignition Gas Models
Burner ignites and
goes out repeatedly
- Glow-Bar Ignition
Gas Models
Is there
insufficient
gas pressure?
Check gas supply
and pressure.
Low flame will
not maintain
sensor conductivity.
Yes
Are the
burner ports
plugged?
Yes
Check burner tubes
for build-up.
Is the
exhaust system
improper or
inadequate?
Yes
Refer to
Installation Manual
for exhaust system
equirements.
No
Does
tumbler have
improper
orifices?
Yes
Tumbler is
equipped for type
of gas specified on
serial plate. If
orifices are different
from that specified
on serial plate,
obtain and install
correct orifices.
No
Is
there inadequate
make-up air?
Yes
Refer to
Installation Manual
for make-up air
requirements.
TMB2141S
Is high limit
thermostat
inoperative?
Refer to
Flowchart 14
.
No
Yes
No
No
Is
burner heat
not holding sensor
contacts open?
Replace sensor.
Yes
No