Troubleshooting
8. Igniter Does Not Shut Off After Gas Ignition – Automatic Pilot Ignition
Gas Models
Igniter does not shut off
after gas ignition -
Automatic Pilot Ignition
Gas Models
Is tumbler
not properly
equipped for
type of gas
being used?
Tumbler is equipped
for type of gas
specified on serial
plate. If tumbler is
equipped for gas
different from that
specified on serial
plate, obtain the
necessary
components to
correct the problem.
Is gas supply
insufficient?
Open partially closed
gas shut-off valve or
correct low gas
pressure.
Is burner
flame
improperly
adjusted?
Refer to
Installation
Manual
for
recommended
burner flame
adjustment.
Is pilot and
electrode
assembly
incorrectly
installed?
Check assembly
for correct
alignment.
Yes
Yes
No
Yes
No
Yes
TMB2137S
No
Is igniter
control
inoperative?
Test igniter
control and
replace if
inoperative.
Refer to wiring
diagram located
on back of
tumbler or in
literature
packet.
Is wiring
incorrect?
Yes
No
Yes
No