70410501
41
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
27. Spark To Pilot Burner, Pilot Lights, No Main Burner – Electronic Pilot
Ignition Models
Spark to pilot burner, pilot
lights, no main burner –
Electronic Pilot Ignition Models
Are there 24 volts
between terminal 3 and
ground on electronic
package?
Is wire
between sensor and
terminal 4 of electronic
package connected
securely?
No
Replace left
coil (main
operator).
Yes
Correct.
No
TMB2154S
Is sensor
securely seated in
pilot burner?
Correct.
Yes
No
Is pilot filter,
tube or orifice
obstructed?
Clear pilot
orifice or use
larger pilot
orifice.
Yes
Yes
Is there a crack in
sensor ceramic
insulator?
Check gas
pressure.
No
Replace
sensor.
No
Yes
Содержание ATB50CG
Страница 2: ......