70410501
11
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
1. Motor Does Not Start
Motor does
not start
Is the
electrical power
off or circuit breaker
fuse blown?
No
Is the
loading door
not closed or switch
inoperative?
Is the
door switch
improperly
adjusted?
No
Check power
supply or replace
fuses.
Yes
Close door or
test switch and
replace if
inoperative.
Yes
Refer to
Installation
Manual
for
door switch
adjustment.
Yes
Is the start circuit
not complete?
Yes
Press
start switch
or test switch
and replace if
inoperative.
Is the motor
inoperative?
Yes
Have motor tested
and replace if
inoperative.
Refer to wiring
diagram.
Yes
Are
improper
coins inserted in
accumulator?
Yes
Check that proper
coins are inserted.
Is the
motor relay
inoperative?
Yes
Test relay and
replace if
inoperative.
Is there
broken, loose, or
incorrect
wiring?
No
TMB2131S-a
No
No
No
Is
accumulator knob
improperly set
after coins were
inserted.
Yes
Turn knob
clockwise to its full
limit of travel.
Is the
run switch
accumulator
inoperative?
Yes
Test run switch
and replace if
inoperative.
No
No
No
continued on
next page
No
Содержание ATB50CG