Troubleshooting
44. OM Reversing Models: No Cylinder Rotation or Reversing Capabilities
208-240 Volt/60 Hertz/3 Phase and 480 Volt/60 Hertz/3 Phase CE Models
208-240 Volt/60 Hertz/3 Phase and 460-480 Volt/60 Hertz/3 Phase CG and CSH Models
OM Reversing Models:
No cylinder rotation or
reversing capabilities
Is there
voltage across the
primary of the
transformer?
TMB2171S-a
Correct wiring
between
transformer and
supply voltage.
Check fuses.
Is there
voltage across
terminals 2 & 3 of the
transformer
secondary?
Replace
transformer.
Yes
No
No
Is there
voltage to the
COM of the door
switch?
Correct wiring
to door switch.
Check fuses.
Is there
voltage to the N.O.
terminal of the door
switch?
Correct wiring
and check
fuses.
Is there
voltage to H2-8 terminal
of micro control?
Correct wiring
between micro
control and door
switch.
Forward
Rotation: Is there
voltage to H2-3
of micro
control?
Make sure unit is
in the forward
portion of rotation.
Replace micro
control.
Forward
Rotation: Is there
voltage across the
coil of the forward
relay?
Correct the
wiring to the
relay.
Forward
Rotation: Is there
voltage to terminals L1,
L2 and L3 of
the forward
relay?
Correct wiring
between relay
and supply
voltage.
Yes
No
Yes
No
No
No
Yes
No
Yes
No
Continued on
next page
Forward
Rotation: Is there
voltage to terminals T1,
T2 and T3 of the
forward relay?
Replace
forward relay.
Yes
Yes
Yes
No
Yes
Содержание ATB50CG