Troubleshooting
35. OM Models: No Start With Cycle Selected, Start Button Pressed and Door
Closed
120 Volt/60 Hertz/1 Phase CG & CSH Nonreversing; 208-240 Volt/60 Hertz/1 or 3 Phase CSH
Nonreversing; 208-240 Volt/60 Hertz/3 Phase CE Nonreversing; 460-480 Volt/60 Hertz/3 Phase
CG, CE and CSH Nonreversing
OM Models: No Start with
cycle selected, start button
pressed and door closed
Is there
voltage to the
primary of the
transformer?
Is there
24 VAC across
terminals 2 & 3 of
transformer
secondary?
Yes
Replace
transformer.
No
TMB2162S-a
Correct wiring to
transformer
primary. Check
fuses.
No
Is there
voltage to the
COM terminal of the
door switch?
Correct wiring
between door
switch and
transformer.
Check fuses.
Is there
voltage to the N.O.
terminal of the door
switch?
Check door switch
for proper
operation. Replace
if necessary.
Is there
voltage to terminal
H2-8 on the micro
control?
Correct wiring
between micro
control and
door switch.
Is there
voltage at terminal
H2-7 on the micro
control?
Replace
micro control.
Is there voltage
across the coil of
motor relay?
Correct wiring
between motor
relay and
micro control.
Is there voltage
to the input of the
motor relay?
Correct wiring
between motor
relay and
supply voltage.
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Continued on
next page
Yes