Troubleshooting
40. MM Models: Fan Motor Does Not Run With Door Closed, Cycle Selected
and Start Button Pressed
208-240 Volt/60 Hertz/3 Phase Gas and Steam Reversing and Nonreversing; 480 Volt/60 Hertz/
3 Phase Gas Nonreversing; 480 Volt/60 Hertz/3 Phase Steam Reversing
NOTE: Make sure fuse on x1 of transformer is operational (240 Volt and 480 Volt/60 Hertz/3 Phase units).
MM Models: Fan motor
does not run with door
closed, cycle selected and
start button pressed
Is there
voltage to the COM
of the door
switch?
TMB2167S
Correct wiring
between door
switch and L1
supply for 208-240
Volt units. Check
between door
switch and X1 of
transformer for 480
Volt units.
Is there
120 VAC to the
N.O. terminal of the
door switch?
Check for proper
operation of
door switch arm
and/or replace
door switch.
Is there 120 VAC
to terminal P2 of the
micro control?
Correct wiring
between door
switch and
micro control.
Is there
120 VAC to
terminal P1 of the
micro control?
Replace
micro control.
Is there
120 VAC across
the coil of the motor
contactor?
Correct wiring to
the coil of motor
contactor.
Replace
motor.
Yes
No
No
Yes
No
Yes
No
No
Is there
voltage to terminals
L1, L2, and L3 of
motor contactor?
Correct wiring
between motor
contactor and
terminals L1, L2,
L3 and TB1.
Is there
voltage at
terminals T1, T2
and T3 of the M
contactor?
Replace motor
contactor.
Is there
voltage to L1,
L2 and L3 of
motor?
Correct wiring
between motor
and motor
contactor.
Yes
Yes
No
No
Yes
No
Yes
Yes