Troubleshooting
43. MM Models: No Heat With Cycle Selected, Unit Running and Calling For
Heat (continued)
208-240 Volt/60 Hertz/3 Phase Gas Reversing
Is
there voltage
across V1 and V2
of the IEI
board?
TMB2170S-b
Does the
unit ignite?
Continue to
next step.
Is there
a spark?
Check for proper
igniter gap. Check
for proper
resistance of high
voltage lead, 5 k
to 25 k ohms.
No
Yes
No
Continued from
previous page
Is there
voltage across
the coils of the
gas valve?
Correct wiring
between gas
valves and IEI
board.
No
Yes
Yes
Is there
a gas flow through
the valve?
Check to see if gas
line is on and that
the gas line was
bled of air. Also,
check for proper
gas pressure.
Yes
No
Unit
operational.
Make sure unit is
not in flame
lockout. Replace
IEI board
if necessary.
No
Yes