52
70410501
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
36. OM Models: No Display After Selecting One Of The ON/SELECT Keys
120 Volt/60 Hertz/1 Phase CG and CSH Nonreversing; 208-240 Volt/60 Hertz/1 Phase CG and
CSH Nonreversing; 208-240 Volt/60 Hertz/3 Phase CG and CSH Reversing/Nonreversing; 208-
240 Volt/60 Hertz/3 Phase CE Reversing/Nonreversing; 460-480 Volt/60 Hertz/3 Phase CG, CE
and CSH Reversing/Nonreversing
OM Models: No display
after selecting one of the
ON/ SELECT keys
Is there voltage
aross the primary of
the transformer?
TMB2163S
Correct wiring
between
transformer and
supply voltage.
Check fuses.
Is there 24 VAC
across terminals 1 & 4
of transformers
secondary?
Replace
transformer.
Is there 24 VAC
across terminals H3-3
and H3-4 on the
micro control?
Correct wiring
between H3 and
transformer.
Check fuses.
Is there voltage
to the input of the
fuse on the micro
control?
Replace
micro
control.
Is there voltage
to the opposite side
of the fuse on the
micro control?
Check fuse
making sure
it is not blown.
Replace if
necessary.
Replace
micro control.
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes
Содержание ATB50CG