Commands in DSR Application Subsystems
DeMUX Rewiring Parameter Commands
220
Agilent 81250 Parallel Bit Error Ratio Tester, Programming Reference, March 2006
:
<
Handle
>
:SGENeral:GLOBal:
SYNChronization:RMODe
Syntax
:<Handle>:SGENeral:GLOBal:SYNChronizat:RMODe <AUTO|TRO|TDET>
Parameters
<AUTO | TRO | TDET>
Sets the modes for DeMUX rewiring.
• AUTO
The automatic mode tries first to rewire with the trace detection
method and, if that fails, with the terminal roundtrip method.
• TRO
(
T
erminal
RO
undtrip) Rewire takes place with the terminal
roundtrip.
• TDET
(
T
race
DET
ection) Rewire takes place with the trace detection
method.
For more information on DeMUX rewiring modes, please refer to
“DEMUX Rewiring Modes”
in the
Agilent 81250 Parallel Bit Error
Ratio Tester System User Guide.
Example
:_test:SGENeral:GLOBal:SYNCchronization:RMODe AUTO
or
:_test:SGENeral:GLOBal:SYNCchronization:RMODe TRO
or
:_test:SGENeral:GLOBal:SYNCchronization:RMODe TDET
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com