Timing Parameter Commands
Commands in DSR Application Subsystems
Agilent 81250 Parallel Bit Error Ratio Tester, Programming Reference, March 2006
185
:PULSe:DELay
Syntax
:<Handle>:SGENeral:
PDATa(*)
:[:SOURce]:PULSe:DELay <Delay>
:<Handle>:SGENeral:
PDATa(*):TERMinal(*)
:[:SOURce]:PULSe:DELay
<Delay>
:<Handle>:SGENeral:
PPULse(*)
[:SOURce]:PULSe:DELay <Delay>
:<Handle>:SGENeral:
PPULse(*):TERMinal(*)
[:SOURce]:PULSe:DELay
<Delay>
:<Handle>[:CGRoup(*)]:MODule(*):
CONNector(*)
:[:SOURce]:PULSe:DELay
<Delay>
Parameters
<Delay>
Delay value in seconds (<NRf>).
Description
Sets the time from the start of the period to the first edge of the pulse.
Reference is the trigger output.
Valid range for E4832A: 0 ... max (3 μs, PERiod).
Valid range for E4861A, E4866A: 0 ... 300 ns.
Valid range for E4861B: 0 ... 200 ns.
Valid range for N4872A/N4874A: 0 ... 200 ns.
If this command is used, the value is interpreted as a timing value
only. This sets
PULSe:DELay:CYCLes
to zero.
Otherwise, if the delay is specified by
PULSe:DELay:CYCLes
and
PULSe:DELay:TIME
, the corresponding delay is calculated. The number
of cycles is converted into seconds and added to the specified
PULSe:
DELay:TIME
value.
Example
:_test:SGEN:PDAT1:PULS:DEL 50e-9
:_test:SGEN1:PDAT1:TERM1:PULS:DEL 50e-9
:_test:SGEN:PDAT1:PULS:DEL 50e-9
:_test:SGEN1:PDAT1:TERM1:PULS:DEL 50e-9
:_test:CGROUP1:MODULE2:CONNECTOR4:PULS:DEL 50e-9
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com