4339B
Front
P
anel
Reset
K
ey
The
Reset
key
resets
all
instrument
settings
and
correction
data
to
the
default
values
.
The
4339B
can
also
be
reset
by
sending
GPIB
commands
:SYST:PRES
and
*RST ,
with
the
same
results
,
except
in
a
couple
of
cases
.
The
following
table
lists
the
dierence
among
the
results
of
pressing
the
Reset
key
and
sending
the
:SYST:PRES
and
*RST
command,
and
also
lists
where
the
settings
are
stored
in.
Data
stored
in
back-up
memory
is
held
for
about
72
hours
after
powering
OFF
.
The
items
saved
by
the
Save
key
or
recalled
by
the
recall
key
are
the
same
as
those
stored
in
the
back-up
memory
.
Data
stored
in
EEPROM
is
not
aected
by
powering
OFF
.
T
able
3-3.
Reset
Settings
Item
Reset
key
SYST:PRES
1
*RST
1
Stored
in
T
est
voltage
output
state
OFF
None
T
est
voltage
level
0
V
Back-up
memory
Current
limit
0.5
mA
Back-up
memory
Measurement
parameter
R
Back-up
memory
Thickness
of
DUT
2
mm
Back-up
memory
Electrode
size
(D1)
50
mm
Back-up
memory
Electrode
size
(AREA)
19.635
mm
2
Back-up
memory
Electrode
size
(PERIMETER )
18.850
cm
Back-up
memory
Electrode
size
(GAP)
1.000
cm
Back-up
memory
Eective
area
coecient
(B)
0
Back-up
memory
Deviation
measurement
OFF
Back-up
memory
Deviation
reference
value
Cleared
Back-up
memory
Measurement
range
mode
A
uto
Back-up
memory
Measurement
range
(A
uto)
Back-up
memory
Measurement
time
mode
Medium
Back-up
memory
A
veraging
rate
1
Back-up
memory
Trigger
mode
Internal
Back-up
memory
Trigger
delay
time
0
s
Back-up
memory
Contact
Check
ON/OFF
state
OFF
Back-up
memory
LimitC
value
0
Back-up
memory
Oset
value
0
Back-up
memory
Comparator
ON/OFF
state
OFF
Back-up
memory
Comparator
limits
MAX/MIN
Back-up
memory
Program
sequence
running
Aborted
None
Program
sequence
OFF
Back-up
memory
Change
time
0
s
Back-up
memory
Interval
time
1
s
Back-up
memory
Memory
size
500
Back-up
memory
Display
mode
Measured
Display
Back-up
memory
Correction
ON/OFF
state
ON
OFF
None
Correction
data
Cleared
EEPROM
Oset-Error
Canceling
OFF
EEPROM
1
\ "
indicates
the
value
is
the
same
as
what
is
indicated
to
the
left.
Function
Reference
3-17
Содержание 4339B
Страница 10: ......
Страница 18: ... ᄌᦝ 0123 45 6789 8 A B C ᄌᦝ 3 DE FG H FG IJ B C K 9 C Copyright 2007 Agilent Technologies ...
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 30: ......
Страница 44: ......
Страница 55: ...4339B Initial Inspection Figure 1 1 Power Cable Supplied Getting Started 1 11 ...
Страница 212: ......
Страница 220: ......
Страница 230: ......
Страница 256: ......
Страница 262: ...4339B Figure B 1 Handler Interface Comparison Output Signals Diagram B 2 Handler Interface Installation ...
Страница 263: ...4339B Figure B 2 Handler Interface Control Output Signals Diagram Handler Interface Installation B 3 ...
Страница 268: ...Procedure 4339B Figure B 5 A1 Main Board B 8 Handler Interface Installation ...