1 - 5
GEN
INFO
CHECKING OF CONNECTION
EC1C0000
CHECKING OF CONNECTION
Dealing with stains, rust, moisture, etc. on the
connector.
1. Disconnect:
●
Connector
2. Dry each terminal with an air bower.
3. Connect and disconnect the connector
two or three times.
4. Pull the lead to check that it will not come
off.
5. If the terminal comes off, bend up the pin
1
and reinsert the terminal into the con-
nector.
6. Connect:
●
Connector
NOTE:
The two connectors “click” together.
7. Check for continuity with a tester.
NOTE:
●
If there in no continuity, clean the terminals.
●
Be sure to perform the steps 1 to 7 listed
above when checking the wireharness.
●
For a field remedy, use a contact revitalizer
available on the market.
●
Use the tester on the connector as shown.