114 Configuration
WAGO-ETHERNET-Zubehör 852
852-1305 8/4-Port 100BASE-T/1000BASE-SX/LX
Manual
1.1.0
Pos: 28.6 /Serie 852 (ETH ERNET-Zubehör)/Konfigurieren/Konsolenport @ 25\mod_1453203786134_21.docx @ 198615 @ 3 @ 1
8.1.2
Console Port
Before accessing the integrated management agent of the industrial managed
switch via a network connection, you first have to configure it via a local
connection or the BOOTP protocol with the default IP address, a subnet mask and
a standard gateway.
After configuring the IP parameters of the industrial managed switch, you can
access the integrated configuration utility from any point in the connected
network or via the Internet. The integrated configuration utility can be called up
via Telnet from any computer connected to the network. In addition, it can be
managed from any computer via a Web browser.
1.
Connect the computer to the console port on the switch using the
appropriate cable.
2.
Use Telnet with the following settings:
Table 27: Default Settings for the Console Port
Setting
Default Value
Terminal Emulation
VT100
Baud Rate
38400
Parity
None
Number of Data Bits
8
Number of Stop Bits
1
Flow Control
None
3.
Press [ENTER] to open the login screen.
Table 28: Login Screen
Setting
Default Value
FW Version 01
FW Version 02 or
higher
Default Username
admin
admin
Default Password
Wago1951
wago
Requirement to establish the connection
Make sure that the terminal or PC is configured for the connection with the above
settings. Otherwise, no connection can be established.
Please refer to the section “Appendix” > … > “RJ-45 Cable” for details on the
cable terminal assignment.
Pos: 28.7 /Dokumentation allgemei n/Glieder ungselemente/---Seitenwechsel--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1