u-blox ZED-F9P Interface Description - Manual
Advance Information
TXT continued
Field
No.
Name
Unit
Format
Example
Description
Field
No.
Name
Unit
Format
Example
Description
0
xxTXT
-
string
$GPTXT
TXT Message ID (xx = current Talker ID)
1
numMsg
-
numeric
01
Total number of messages in this transmission, 01..
99
2
msgNum
-
numeric
01
Message number in this transmission, range 01..xx
3
msgType
-
numeric
02
Text identifier, u-blox receivers specify the type of
the message with this number.
00: Error
01: Warning
02: Notice
07: User
4
text
-
string
www.u-blox.
com
Any ASCII text
5
cs
-
hexadecimal
*67
Checksum
6
<CR><LF>
-
character
-
Carriage return and line feed
4.2.16 VLW
4.2.16.1 Dual ground/water distance
Message
VLW
Description
Dual ground/water distance
Firmware
Supported on:
•
u-blox 9 with protocol version 27
Type
Output Message
Comment
The distance traveled, relative to the water and over the ground. This message relates to
the
ID for CFG-MSG
Number of fields
Message Info
0xF0 0x0F
11
Message Structure:
$xxVLW,twd,twdUnit,wd,wdUnit,tgd,tgdUnit,gd,gdUnit*cs<CR><LF>
Example:
$GPVLW,,N,,N,15.8,N,1.2,N*06
Field
No.
Name
Unit
Format
Example
Description
0
xxVLW
-
string
$GPVLW
VLW Message ID (xx = current Talker ID)
1
twd
nm
numeric
-
Total cumulative water distance, not output
2
twdUnit
-
character
N
Fixed field: nautical miles
3
wd
nm
numeric
-
Water distance since reset, not output
4
wdUnit
-
character
N
Fixed field: nautical miles
5
tgd
nm
numeric
15.8
Total cumulative ground distance
6
tgdUnit
-
character
N
Fixed field: nautical miles
7
gd
nm
numeric
1.2
Ground distance since reset
8
gdUnit
-
character
N
Fixed field: nautical miles
UBX-18010854 - R04
Advance Information
Page 25 of 259