COMPONENT MAINTENANCE MANUAL
Publication No. 051019-1 Rev H
Page 82
33-46-00
AS9100 Certified
Rev G
26-Mar-2014
Figure 63 - Temperature Sensor
NOTE: The sensor must be installed flat surface down to ensure proper sensing of
lamp temperature (Figure 63).
NOTE: When fitting the Nomex paper, ensure that it is folded so that the sensor lies
between the two folds before clamping the sensor in position (Figure 63).
Figure 64 - Temperature Sensor Orientation
NOTE: Ensure the wires pass out over the centre of the heat sink and then back over
the mounting plate to the exit hole in the lamp housing (Figure 64).
Hole location
for temperature
sensor wires
A039