J. Trakka Control Panel Status Messages
Table 10 - TCP Status Messages
Function
Display Text
Normal operation
(system deployed and filter one selected)
Selecting a new filter
1
(system deployed previous filter was 1)
System POSTing
Is displayed until the TCP receives status from the PCIU
that the system is ready for operation.
The bottom line of the display scrolls through the software
install software part number and version.
Alternate Command mode active. Symbol displayed at top
right while the filter toggle switch is in the ENT position.
(system deployed and filter 1 selected)
Calibration Mode – message on bottom line displayed for
two seconds, symbol at top right displayed while
calibration Mode active (unless overridden by Alternate
Command mode symbol).
(system deployed and filter 1 selected)
Camera Offset Saved – message displayed for two
seconds.
(system deployed and filter 1 selected)
Stow Position Set – message displayed for two seconds.
(system deployed and filter 1 selected)
Deploy Position Set – message displayed for two
seconds.
(system deployed and filter1 selected)
WOW Input Active – message displayed for two seconds
when the lamp on command is sent.
2
(system deployed and filter1 selected)
Not Armed – message displayed for two seconds when
the lamp on command is sent.
2
(system deployed and filter1 selected)
Moving to Deploy Position
(filter1 selected)
Moving to Stow Position
(filter1 selected)
NOTE 1: ‘N’ represents the newly selected filter number.
NOTE 2: This function is only available when the TCP is connected directly to the PCIU.
If the TCP is connected to the CIU then the message is only available if the lamp is
commanded by controls on the TCP or Grip Hand Controller. The TCP is inactive if the
lamp is controlled by an additional discrete CIU input.
F 1
F 1
F N
P O S T
.
.
.
X X X X X X X X
F 1
F 1
C
S L V
C A L
F 1
S L V
S E T
F 1
S T O W
S E T
F 1
D P L Y
S E T
F 1
W O W
A C T V
F 1
N O T
A R M
F 1
D P L Y I N G
F 1
S T O W I N G