COMPONENT MAINTENANCE MANUAL
Publication No. 051019-1 Rev H
Page 107
33-46-00
AS9100 Certified
Rev G
26-Mar-2014
(f) Install the outer and inner cases in accordance with Chapter 5, I, (2).
(g) Install the lamp assembly in accordance with Chapter 5, H.
C. Cleaning the Trakka Control Panel Frontal Surface
(1) Use a soft bristle brush to clean away surface dust or fungus from the switches and LED display.
NOTE: Do not use compressed air as this may force contaminates into the interior of the
unit.
(2) Apply a small quantity of Isopropyl Alcohol (IPA) to a lint free cloth.
(3) Wipe the surfaces, switches and LED display with the damp, lint free cloth.
NOTE: The IPA may leave a small amount of residue on the LED display and surfaces.
(4) Clean away any residue with the aid of a dry, lint free cloth.
D. Cleaning the Grip Hand Control
(1) Use a soft bristle brush to clean away surface dust or fungus from the switches and seven
segment display.
NOTE: Do not use compressed air as this may force contaminates into the interior of the
unit.
(2) Apply a small quantity of Isopropyl Alcohol (IPA) to a lint free cloth.
(3) Wipe the surfaces, switches and seven segment display with the damp, lint free cloth.
NOTE: The IPA may leave a small amount of residue on the display and surfaces.
(4) Clean away any residue with the aid of a dry, lint free cloth.
Rev H
10 Dec 2015
AIRBUS HELICOPTERS: CMM L334M6304E01 ISSUE: B PAGE 125 OF 165
The document reference is online, please check the correspondence between the online documentation and the printed version.