Machine Faults (continued)
Fault
ID
Fault Title
Controller(s)
Affected
Fault
Condition/Circuit
Description
Additional Notes
Service Actions
P156C Traction
Controller
- Internal
Hardware
Failure
SC5, SC6
An internal
component of
the controller
fails in the
indicated
traction motor
controller.
Traction is
disabled.
1.
Replace and program the traction
motor controller (contact an Authorized
Toro Distributor for assistance).
2.
Cycle the key switch.
3.
Use the InfoCenter to calibrate the
traction motor controller.
For SC5, calibrate the traction pedal
first, then the traction motors.
For SC6, calibrate the traction motors.
P156D Traction
Controller
- Internal
Software
Failure
SC5, SC6
An unexpected
software error
occurs in
the indicated
traction motor
controller.
Traction is
disabled.
1.
Replace and program the traction
motor controller (contact an Authorized
Toro Distributor for assistance).
2.
Cycle the key switch.
3.
Use the InfoCenter to calibrate the
traction motor controller.
For SC5, calibrate the traction pedal
first, then the traction motors.
For SC6, calibrate the traction motors.
P156E Traction Motor
Software -
Hardware
Incompatibility
SC5, SC6
The software is
not compatible
with the
hardware in
the indicated
traction motor
controller.
Traction is
disabled.
1.
Replace and program the traction
motor controller (contact an Authorized
Toro Distributor for assistance).
2.
Cycle the key switch.
3.
Use the InfoCenter to calibrate the
traction motor controller.
For SC5, calibrate the traction pedal
first, then the traction motors.
For SC6, calibrate the traction motors.
P1A01 Battery
Charging - High
Temp Shutdown
SC8
A Li-ion battery
cell temperature
is greater than
60° C (140° F).
Battery contactor
in Li-ion battery
controller is
opened.
1.
Allow the machine to cool before
charging.
2.
Disconnect the charger for 5 seconds
and then reconnect.
3.
Charge the machine in the shade or a
cooler environment.
P1A02 Battery
Charging- Low
Temp Shutdown
SC8
A Li-ion battery
cell temperature
is less than -10°
C (14° F).
Battery contactor
in Li-ion battery
controller is
opened.
1.
Allow the machine to warm before
charging.
2.
Disconnect the charger for 5 seconds
and then reconnect.
P1A11 Battery
Charging
Voltage - High
SC8
A Li-ion battery
cell voltage is
greater than
4.2V.
Battery contactor
in Li-ion battery
controller is
opened.
1.
Ensure the correct charger is being
used.
2.
Check the charger for faults.
3.
Charge the machine with a known
good charger or replace the charger.
Troubleshooting: Battery Charger Error and Fault Codes
Page 3–28
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B