Machine Faults (continued)
Fault
ID
Fault Title
Controller(s)
Affected
Fault
Condition/Circuit
Description
Additional Notes
Service Actions
P0A3C Traction Motor
Controller - High
Temp Warning
SC5, SC6,
T5
The temperature
is greater than
90°C (194° F)
in the indicated
traction motor
controller.
Traction motor
current is limited
on a linear
basis until the
temperature
drops below
90°C (194° F)
or exceeds 100°
C (212° F).
1.
Reduce the ground speed.
2.
Check for mechanical resistance in the
wheels that would make the motors
work extra hard.
3.
Replace and program the traction
motor controller (contact an Authorized
Toro Distributor for assistance). The T5
controller is part of the motor assembly
and is not replaceable separately.
4.
Cycle the key switch.
5.
Use the InfoCenter to calibrate the
traction motor controller.
For SC5, calibrate the traction pedal
first, then the traction motors.
For SC6, calibrate the traction motors.
P0A3E Starter/Generator
Controller -
High Temp
Warning
T6
The
starter/generator
controller
temperature is
greater than 90°
C (194° F).
Starter/Generator
current is limited
on a linear
basis until the
temperature
drops below 90°
C (194° F) or
exceeds 100° C
(212° F).
Note:
This fault is
not produced by
a bad sensor.
1.
Clean the air intake screen on the back
of the starter/generator. Be sure the
starter/generator is pulling air through
the air intake by feeling with your hand
or by testing with a piece of paper.
2.
Let the machine cool.
3.
Reduce the cutting loads by reducing
the reel speed or reducing mow speed.
4.
Replace and program the
starter/generator controller (contact
an Authorized Toro Distributor for
assistance).
P0A44 Traction Motor
Speed - High
SC5, SC6,
T5
The ground
speed is more
than the allowed
maximum speed
of the machine
as measured
by the indicated
traction motor.
Traction is
disabled.
1.
Inspect the wiring of the speed
sensors.
2.
Check supply voltage to the speed
sensor.
3.
Replace the traction motor.
For SC5 and SC6, use the InfoCenter
to calibrate the traction motors.
For T5, program the traction motor
(contact an Authorized Toro Distributor
for assistance).
P0A54 Traction Motor
Controller -
Over Current
SC5, SC6,
T5
The current draw
exceeds the
hardware and
software limits
of the indicated
traction motor.
Traction is
disabled.
1.
Cycle the key switch to clear the fault.
2.
Contact an Authorized Toro Distributor
or the Toro Technical Assistance
Center and report that this fault
occurred.
P0A5A Starter/Generator
Current Sensor
Out of Range
T6
One of the
sensors
inside the
starter/generator
controller fails.
PTO and
starter/generator
is disabled.
1.
Cycle the key switch.
2.
If the fault repeats, replace and
program the starter/generator
controller (contact an Authorized Toro
Distributor for assistance).
Troubleshooting: Battery Charger Error and Fault Codes
Page 3–20
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B