Battery Charger Error and Fault Codes (Model
04590)
If a battery charger error or fault appears, additional information may be available by disconnecting the
charger, connecting the batteries to the machine, and using the machine InfoCenter to check for any
active machine faults.
Problem
Possible Cause
Corrective Action
Battery high voltage
Ensure that the battery voltage is
correct and the cable connections are
secure.
Codes E-0-0-1, or E-0-4-7
Ensure that the battery is in good
condition.
Code E-0-0-4
Lithium-ion battery controller (BMS) or
battery fault detected
Forward a copy of the battery output
file (.BDS) to Toro Service (contact
an Authorized Toro Distributor for
assistance).
Battery amp hour limit exceeded
Check all battery cable connections for
corrosion or damage. Clean and repair
battery connections as necessary.
Batteries may be deeply discharged.
Battery replacement may be necessary.
Code E-0-0-7
Disconnect and connect the charger to
the batteries to reset this error.
Code E-0-1-2
Reverse polarity error
Ensure that the battery cables are
connected correctly and that the cable
connections are clean and secure.
Code E-0-2-3
High AC voltage error (greater than
270 VAC)
Connect the charger to an AC power
source that provides stable AC power
between 85 - 270 VAC at 45-65 Hz.
Code E-0-2-4
Charger failed to initialize
Disconnect the charger AC input and
battery connections for 30 seconds,
then reconnect the charger.
Code E-0-2-5
Low AC voltage oscillation error
The charger requires an AC power
source that provides stable AC power
between 85 - 270 VAC at 45-65 Hz.
Confirm the AC power supply capacity
and verify AC input cable gauge.
Code E-0-3-7
Re-programming failed
Software upgrade failure or script
operation failure. Ensure that the new
software is correct.
Codes E-0-2-9, E-0-3-0, E-0-3-2,
E-0-4-6, or E-0-6-0
Communication error with battery
Ensure that the connection of the signal
wires to each battery is clean and
secure.
Internal charger fault
Remove the charger AC connection
and battery connection for a minimum
of 30 seconds, then reconnect the
charger.
Codes F-0-0-1, F-0-0-2, F-0-0-3,
F-0-0-4, F-0-0-5, F-0-0-6, or F-0-0-7
The battery charger may require
replacement (contact an Authorized
Toro Distributor for assistance).
Troubleshooting: Battery Charger Error and Fault Codes
Page 3–50
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B