Testing the Front Traction Motor Controllers (continued)
IMPORTANT
Do not allow areosol protectant to spray into the front traction
motor controller multi-pin connector. Install the wire harness
connector or cover the connector before applying spray
protectant. Spray protectant can adversely effect the precise fit
of a multi-pin connector.
G. Lift the rubber boots from the cable terminals and coat the terminals with
battery terminal protector Toro Part No. 107-0392 to reduce corrosion. Fit
the rubber boots securely over the terminals.
H. Update the machine software; contact an Authorized Toro Distributor
for assistance.
10. Calibrate the front traction motors before returning the machine to service;
refer to
Calibrating the Front Traction Motors (page 5–56)
.
Electrical System: Testing the Electrical Components
Page 5–54
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B