Harmony Series 2 Homelift - XH00200
Issue: D
Page 71 of 106
Fault Finding
Before undertaking any detailed Fault Finding, confirm that the basic fault finding in the user
instructions has been undertaken.
Notes on fault finding
1) Before commencing fault finding using the flow chart:-
a) Check the status of all LED’s and fuses – and take any necessary action
b) Check door is closed
c) Ideally the lift should be in mid position i.e. off its limit switches
d) Note that LED’s on the sling board are only illuminated during the “Light on” period
(initiated by up/down/door signal) and when the user LED panel is disconnected.
2) Voltage checks indicate 13.7V this will vary according to battery condition and where it is
being measured – but under no load conditions should never be below 11.8V
3) If the alarm sounds when lift ascending the float switch is closed – detecting a full fluid
catch tank.
Phone Support Fault Finding
If the door is off the D-tent –
Note: On a Harmony Lift the Emergency Door key must be used to unlock the door
even when parked at level.
1. Power the door by pressing the top safe edge on the latch side and holding it down
fully when the door is just short of its fully open position.
2. Manually close the door until the D-tent engages. Then release the safe edge
channel and the door will close fully.
3. It should know be back in its normal state.
Power LED.
The Red power LED on the user display should be OFF when the lift is parked at level but
will be ON during operation.
If the LED is ON after 10 minutes of being parked then this indicates the Mains are off.
User Display LED's.
All have a key fob to enable the lift. (A = on / B = off)
Sling Top Safe edge / Up Car Safe edge obstruction / Up Underpan obstruction – 1 Green
out.
Up Trapdoor – 2 Greens Out.
Underpan Down obstruction – 1 Yellow Out.
Trapdoor Down obstruction – 2 Yellows Out.
Note: Top Limit red plunger sticking down will cause 2 Green LED’s to extinguish.
EMERGENCY LOWERING ON ANY MODEL OF HARMONY IS ONLY TO BE CARRIED
OUT IF SOMEONE IS TRAPPED INSIDE THE LIFT - not as a means of down operation
until an engineer can attend.
Summary of Contents for HARMONY 2 Series
Page 6: ...Harmony Series 2 Homelift XH00200 Issue D Page 6 of 106...
Page 8: ...Harmony Series 2 Homelift XH00200 Issue D Page 8 of 106...
Page 10: ...Harmony Series 2 Homelift XH00200 Issue D Page 10 of 106...
Page 18: ...Harmony Series 2 Homelift XH00200 Issue D Page 18 of 106 FIG 5 Harmony Lift Loading Diagram...
Page 52: ...Harmony Series 2 Homelift XH00200 Issue D Page 52 of 106...
Page 56: ...Harmony Series 2 Homelift XH00200 Issue D Page 56 of 106...
Page 62: ...Harmony Series 2 Homelift XH00200 Issue D Page 62 of 106...
Page 64: ...Harmony Series 2 Homelift XH00200 Issue D Page 64 of 106...
Page 66: ...Harmony Series 2 Homelift XH00200 Issue D Page 66 of 106...
Page 68: ...Harmony Series 2 Homelift XH00200 Issue D Page 68 of 106...
Page 70: ...Harmony Series 2 Homelift XH00200 Issue D Page 70 of 106...
Page 75: ...Harmony Series 2 Homelift XH00200 Issue D Page 75 of 106 CE1654 PCB Layout Detail Drawing...
Page 76: ...Harmony Series 2 Homelift XH00200 Issue D Page 76 of 106...
Page 78: ...Harmony Series 2 Homelift XH00200 Issue D Page 78 of 106...
Page 80: ...Harmony Series 2 Homelift XH00200 Issue D Page 80 of 106...
Page 82: ...Harmony Series 2 Homelift XH00200 Issue D Page 82 of 106...
Page 84: ...Harmony Series 2 Homelift XH00200 Issue D Page 84 of 106...
Page 106: ...Harmony Series 2 Homelift XH00200 Issue D Page 106 of 106...