Door Operator Adjustment
Door closed and beak fully engaged:
x
Should be some free movement in latch cam i.e. door should stop on side frame (not
beak) – adjust on slotted hole if necessary
x
Switch roller should be free in latch cam cut out.
x
Once set, lock beak up tight.
Note:- Further adjustment is available on door hinges and centre brace jacking bolts.
Automatic Door Closer Set Up Procedure
1.
Ensure all wiring connections are as shown on ‘Wiring Diagram 3 – Harmony W/C Control
PCB (7 core colour)’.
2.
Disconnect motor terminals and power the actuator to its centre position. Re-connect the
motor terminals. The system should now operate when the door button is pressed.
3.
Adjust the current limit potentiometer (I lim) – VR3 on Sling PCB – to a state where the door
will reverse direction when a reasonable force is applied to it when it is operating.
4.
Reduce the limit switch override timer potentiometer – VR2 on Sling PCB – to zero and
operate the door. Set the close limit microswitch such that the door stops just as the door beak
is entering the latch, then increase the override potentiometer to increase the length of time the
controller overrides the close limit switch. This is to ensure the door is firmly closed without the
current limits operating.
5.
Adjust auto close potentiometer so that the door closes automatically after approximately 1
minute if door is left open (VR4).
6.
Finally to ensure closed limit switch connections are correct, press the door button to close
door and then press door button twice rapidly in succession. If the actuator ceases to operate
when door button is pressed again the common and N/C connections of J3 are wired incorrectly.
By reversing these connections the actuator will operate normally.
7.
Set the Open Limit Switch on the actuator (purple wires) to a position that gives complete
wheelchair access to the carriage (90 degrees to car side).
8.
Ensure the emergency detent operates correctly by releasing the door lock with the key and
applying reasonable pressure to the door. It should push open – adjust the springs as shown if
necessary to achieve correct setting.
Door Open Limit Switch
Door Closed Limit Switch
Door Proving Switch
Manually pull door closed to
ensure door proving switch is
just made.
Detent Assembly Springs
Summary of Contents for HARMONY 2 Series
Page 6: ...Harmony Series 2 Homelift XH00200 Issue D Page 6 of 106...
Page 8: ...Harmony Series 2 Homelift XH00200 Issue D Page 8 of 106...
Page 10: ...Harmony Series 2 Homelift XH00200 Issue D Page 10 of 106...
Page 18: ...Harmony Series 2 Homelift XH00200 Issue D Page 18 of 106 FIG 5 Harmony Lift Loading Diagram...
Page 52: ...Harmony Series 2 Homelift XH00200 Issue D Page 52 of 106...
Page 56: ...Harmony Series 2 Homelift XH00200 Issue D Page 56 of 106...
Page 62: ...Harmony Series 2 Homelift XH00200 Issue D Page 62 of 106...
Page 64: ...Harmony Series 2 Homelift XH00200 Issue D Page 64 of 106...
Page 66: ...Harmony Series 2 Homelift XH00200 Issue D Page 66 of 106...
Page 68: ...Harmony Series 2 Homelift XH00200 Issue D Page 68 of 106...
Page 70: ...Harmony Series 2 Homelift XH00200 Issue D Page 70 of 106...
Page 75: ...Harmony Series 2 Homelift XH00200 Issue D Page 75 of 106 CE1654 PCB Layout Detail Drawing...
Page 76: ...Harmony Series 2 Homelift XH00200 Issue D Page 76 of 106...
Page 78: ...Harmony Series 2 Homelift XH00200 Issue D Page 78 of 106...
Page 80: ...Harmony Series 2 Homelift XH00200 Issue D Page 80 of 106...
Page 82: ...Harmony Series 2 Homelift XH00200 Issue D Page 82 of 106...
Page 84: ...Harmony Series 2 Homelift XH00200 Issue D Page 84 of 106...
Page 106: ...Harmony Series 2 Homelift XH00200 Issue D Page 106 of 106...