DESCRIPTION
The LUPINE BR Anchor is designed for implantation
within a pre-drilled bone hole site and provides a means
for firmly securing soft tissue to bone using USP #2
suture. This operative suture is provided without needles
and is held in a USP #2 suture loop eyelet. The anchor is
preloaded on an inserter for open or arthroscopic repairs.
MATERIALS
Anchor: Composite made of absorbable Poly (lactide-
coglycolide) polymer and Tricalcium phosphate (TCP).
1. ORTHOCORD™ Suture is a synthetic, sterile,
braided, composite suture composed of dyed (D&C
Violet #2 or D&C Blue #6) absorbable polydiaxanone
(PDS®) and un-dyed non-absorbable polyethylene.
The partially absorbable suture is coated with a
copolymer of 90% caprolactone and 10% glycolide.
The PDS copolymer has been shown to be
nonantigenic, nonpyrogenic and elicits only a slight
tissue reaction during absorption.
INSERTER
Handle:
Polycarbonate
Shaft:
Stainless steel
INDICATIONS
The LUPINE BR Anchor System is indicated for use in
soft tissue to bone fixation in association with adequate
postoperative immobilization as follows:
OPEN PROCEDURES
SHOULDER
1. Bankart Repair
2. SLAP lesion repair
3. Rotator cuff repair
4a. Capsule shift/capsulo-labral reconstruction, at the
anterior glenoid rim site
4b. Capsule shift/capsulo-labral reconstruction at the
lesser tuberosity of the humerus
5. Biceps tenodesis
6. Acromio-clavicular separation
7. Deltoid repair
ELBOW
1. Biceps tendon reattachment
2. Tennis elbow repair
ANKLE
1. Achilles tendon repair/reconstruction
2. Lateral stabilization
3. Medial stabilization at the medial talus site
Foot: Hallux Valgus reconstruction
4. Midfoot reconstruction
KNEE
1. Medial collateral ligament repair
2. Lateral collateral ligament repair
3. Joint capsule closure to anterior proximal tibia
4. Posterior oblique ligament or joint capsule to tibia repair
5. Extra capsular reconstruction/ITB tenodesis
6. Patellar ligament and tendon avulsion repairs
ARTHROSCOPIC PROCEDURES
SHOULDER
1. Bankart repair
2. SLAP lesion repair
3. Rotator cuff repair
4. Capsule shift repair (glenoid rim)
CONTRAINDICATIONS
• Surgical procedures other than those listed in the
INDICATIONS section.
• Pathological conditions of bone such as cystic changes
or severe osteopenia, which would inhibit the drilling of
a precise hole or compromise secure anchor fixation.
• Pathologic conditions in the soft tissue to be attached
which would impair secure fixation by suture.
Summary of Contents for LUPINE BR Anchor
Page 31: ...31 1 Bankart 2 SLAP 3 4 LUPINE BR 3 6 kg LUPINE BR LUPINE BR ORTHOCORD LUPINE BR...
Page 32: ...32 2 9mm 18mm 1 Stabilization DePuy Mitek 2 9mm 18mm 2 LUPINE BR 3...
Page 46: ...46 ORTHOCORD LUPINE BR 2 9 18...
Page 58: ...58 3 4 LUPINE BR 8 lbs LUPINE BR LUPINE BR ORTHOCORD LUPINE BR 2 9mm 18mm...
Page 59: ...59 1 18mm 2 9mm DePuy 2 LUPINE BR 3 LUPINE BR 5 lbs 4 5 8 lbs 6 LUPINE BR...
Page 61: ...61...
Page 62: ...62...