10
Technical data and notes
Page 122 of
135
G a s Q u a l i t y A n a l y z e r
GasLab Q2
10.2.1 Type plates
The type plate with the most important information is located under the operation panel, behind the sight
glass. These information must be observed and complied with in every case. If the type plate is covered
by the sand protection, this information can be read on an additional type plate outside of housing. The
following figure shows the position of the type plates.
Figure 10.2: Example Position of main type plate
Depending on d
istribution area
of the device, the type plate varies in
the language and in the list of included
standards or regulations
. See type plate examples below.
Type plate variations
Information
Manufacturer and manufacturer
address with the address of the
production site
Kind of Device Type designation
Serial number and
year of construction MM / YYYY
2 D-Matrix Code and
warning mark to read the manual
Gas input pressure range *
Ambient temperature range
Protection class (IP)
Voltage and power consumption
Procured approvals**
(For EU) Approval number DEKRA
15.ATEX0113X / IECEx DEK 15.0075X
CE mark with auditor number
Warning and connection notes are for several languages onan extra lable
Ex-classification: (II 2G) (A) Ex db IIC
T4 Gb
Figure 10.3: Example main type plate
* On request, devices for 0.05 MPa (g) inlet pressure are available
** Not all certificates and approvals are listed here. The information on the device applies!
The FM approval is requested. It is expected for mid-2017.
Approval number: FM17US0040X / FM17CA0027X
Class I Div 2 Groups ABCD Truppen ABCD T4