Command Line Interface
4-48
4
This command sets the interval that the system waits for a user to log into the CLI.
Use the
no
form to restore the default.
Syntax
timeout login response
[
seconds
]
no timeout login response
seconds
- Integer that specifies the timeout interval.
(Range: 0 - 300 seconds; 0: disabled)
Default Setting
• CLI: Disabled (0 seconds)
• Telnet: 600 seconds
Command Mode
Line Configuration
Command Usage
• If a login attempt is not detected within the timeout interval, the connection is
terminated for the session.
• This command applies to both the local console and Telnet connections.
• The timeout for Telnet cannot be disabled.
• Using the command without specifying a timeout restores the default setting.
Example
To set the timeout to two minutes, enter this command:
Related Commands
silent-time (4-50)
exec-timeout (4-14)
This command sets the interval that the system waits until user input is detected.
Use the
no
form to restore the default.
Syntax
exec-timeout
[
seconds
]
no exec-timeout
seconds
- Integer that specifies the number of seconds.
(Range: 0-65535 seconds; 0: no timeout)
Default Setting
10 minutes
Console(config-line)#timeout login response 120
Console(config-line)#
Summary of Contents for 6152PL2 FICHE