Flow Sampling Commands
4-107
4
Example
This example sets the time out to 1000 seconds.
This command configures the IP address and UDP port used by the Collector. Use
the
no
form to restore the default settings.
Syntax
sflow destination
ipv4
ip-address
[
destination-udp-port
]
no sflow destination
•
ip-address
- IP address of the sFlow Collector.
•
destination-udp-port
- The UDP port on which the Collector is listening for
sFlow streams. (Range: 0-65534)
Default Setting
IP Address: null
UDP Port: 6343
Command Mode
Interface Configuration (Ethernet)
Example
This example configures the Collector’s IP address, and uses the default UDP port.
This command configures the maximum size of the sFlow datagram header. Use the
no
form to restore the default setting.
Syntax
sflow max-header-size
max-header-size
no max-header-size
max-header-size
- The maximum size of the sFlow datagram header.
(Range: 64-256 bytes)
Default Setting
128 bytes
Command Mode
Interface Configuration (Ethernet)
Console(config)#interface ethernet 1/9
Console(config-if)#sflow timeout 10000
Console(config-if)#
Console(config)#interface ethernet 1/9
Console(config-if)#sflow destination ipv4 192.168.0.4
Console(config-if)#