Example
banner configure dc-power-info
This command is use to configure DC power information displayed in the banner.
Use the
no
form to restore the default setting.
Syntax
banner configure dc-power-info floor
floor-id
row
row-id
rack
rack-id
electrical-circuit
ec-id
no banner configure dc-power-info
[
floor
|
row
|
rack
|
electrical-circuit
]
•
floor-id
- The floor number.
•
row-id
- The row number.
•
rack-id
- The rack number.
•
ec-id
- The electrical circuit ID.
Maximum length of each parameter: 32 characters
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The
banner configure dc-power-info
command interprets spaces as data input boundaries. The use of underscores
( _ ) or other unobtrusive non-letter characters is suggested for situations
where white space is necessary for clarity.
Example
banner configure department
This command is used to configure the department information displayed in the
banner. Use the
no
form to restore the default setting.
Syntax
banner configure department
dept
-
name
no banner configure company
dept-name
- The name of the department.
(Maximum length: 32 characters)
Console(config)#banner configure company Edgecore Networks
Console(config)#
Console(config)#banner configure floor 3 row 15 rack 24
electrical-circuit 48v-id_3.15.24.2
Console(config)#