28.5.21 LESENSE_IFC - Interrupt Flag Clear Register
Offset
Bit Position
0x058
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Access
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
(R)W1
Name
Bit
Name
Reset
Access Description
31:23
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
22
CNTOF
0
(R)W1
Clear CNTOF Interrupt Flag
Write 1 to clear the CNTOF interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
21
BUFOF
0
(R)W1
Clear BUFOF Interrupt Flag
Write 1 to clear the BUFOF interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
20
BUFLEVEL
0
(R)W1
Clear BUFLEVEL Interrupt Flag
Write 1 to clear the BUFLEVEL interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt
flags (This feature must be enabled globally in MSC.).
19
BUFDATAV
0
(R)W1
Clear BUFDATAV Interrupt Flag
Write 1 to clear the BUFDATAV interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt
flags (This feature must be enabled globally in MSC.).
18
DECERR
0
(R)W1
Clear DECERR Interrupt Flag
Write 1 to clear the DECERR interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
17
DEC
0
(R)W1
Clear DEC Interrupt Flag
Write 1 to clear the DEC interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags (This
feature must be enabled globally in MSC.).
16
SCANCOMPLETE
0
(R)W1
Clear SCANCOMPLETE Interrupt Flag
Write 1 to clear the SCANCOMPLETE interrupt flag. Reading returns the value of the IF and clears the corresponding inter-
rupt flags (This feature must be enabled globally in MSC.).
15
CH15
0
(R)W1
Clear CH15 Interrupt Flag
Write 1 to clear the CH15 interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
14
CH14
0
(R)W1
Clear CH14 Interrupt Flag
Write 1 to clear the CH14 interrupt flag. Reading returns the value of the IF and clears the corresponding interrupt flags
(This feature must be enabled globally in MSC.).
Reference Manual
LESENSE - Low Energy Sensor Interface
silabs.com
| Building a more connected world.
Rev. 1.1 | 984