26.5.2 ADCn_CMD - Command Register
Offset
Bit Position
0x008
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0
0
0
0
Access
W1
W1
W1
W1
Name
Bit
Name
Reset
Access Description
31:4
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
3
SCANSTOP
0
W1
Scan Sequence Stop
Write a 1 to stop scan sequence.
2
SCANSTART
0
W1
Scan Sequence Start
Write a 1 to start scan sequence.
1
SINGLESTOP
0
W1
Single Channel Conversion Stop
Write a 1 to stop single channel conversions.
0
SINGLESTART
0
W1
Single Channel Conversion Start
Write to 1 to start converting in single channel mode.