Bit
Name
Reset
Access Description
14
GPCRC
0
RW
General Purpose CRC access control bit
Access control only for GPCRC
13
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
12
FPUEH
0
RW
FPU Exception Handler access control bit
Access control only for FPUEH
11
EMU
0
RW
Energy Management Unit access control bit
Access control only for EMU
10
PRS
0
RW
Peripheral Reflex System access control bit
Access control only for PRS
9
VDAC0
0
RW
Digital to Analog Converter 0 access control bit
Access control only for VDAC0
8
CRYPTO0
0
RW
Advanced Encryption Standard Accelerator 0 access control bit
Access control only for CRYPTO0
7
CRYOTIMER
0
RW
CryoTimer access control bit
Access control only for CRYOTIMER
6
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
5
CMU
0
RW
Clock Management Unit access control bit
Access control only for CMU
4:3
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
2
ADC0
0
RW
Analog to Digital Converter 0 access control bit
Access control only for ADC0
1
ACMP1
0
RW
Analog Comparator 1 access control bit
Access control only for ACMP1
0
ACMP0
0
RW
Analog Comparator 0 access control bit
Access control only for ACMP0
Reference Manual
SMU - Security Management Unit
silabs.com
| Building a more connected world.
Rev. 1.1 | 372