Operating the Sensor
Setting
item
Bank Setting value/
default value
General description
5, 6
The bank is changed to number 5 or 6.
7, 8
The bank is changed to number 7 or 8.
Input terminal
settings
IN1: Reset
IN2: Hold
IN3: Trigger
1
The bank is changed to number 1.
2
The bank is changed to number 2.
3
The bank is changed to number 3.
4
The bank is changed to number 4.
5
The bank is changed to number 5.
6
The bank is changed to number 6.
7
The bank is changed to number 7.
8
The bank is changed to number 8.
Baud rate
N
Select the communication baud rate.
9.6K
9,600 bps
19.2K
19,200 bps
38.4K
38,400 bps
57.6K
57,600 bps
115K
115,000 bps
230K
230,000 bps
460K
460,000 bps
921K
921,000 bps
2.0M
2.0 Mbps
4.0M
4.0 Mbps
Axis dir
N
Set the increase/decrease direction of the measured value height with the measurement center
set as 0 mm.
Near+
Set the side close to the head as positive (+).
Far+
Set the side far from the head as positive (+).
On Timing
N
Set either within range or outside of range (as specified by the thresholds) as output judgment criteria.
Out range
Output turns on when the value is outside the range specified by the threshold.
In range
Output turns on when the value is within the range specified by the threshold.
Lang/
言語
N
Select the screen’s display language.
JPN/
日
Information will be displayed in Japanese.
ENG/
英
Information will be displayed in English.