Offset
The offset input operation varies depending on the value of the
“Offset target” setting.
The offset input operation is executed when input turns off.
When “Offset target” is “Indivi”
Input time
Operation
230 ms or less
Set the offset on OUT1.
430 ms or less
Set the offset on OUT2.
630 ms or less
Set the offset on OUT3.
830 ms or less
Clear the offset from OUT1.
1030 ms or less
Clear the offset from OUT2.
1230 ms or less
Clear the offset from OUT3.
More than 1230 ms
Clear all the offsets as a batch.
When “Offset target” is “All”
Input time
Operation
330 ms or less
Set the offset on OUT1 to OUT3 as a batch.
More than 330 ms
Clear all the offsets from OUT1 to OUT3 as a batch.
When “Offset target” is “OUT1” to “OUT3”
Input time
Operation
330 ms or less
Set the offset on OUT1, OUT2, or OUT3.
More than 330 ms
Clear the offset from OUT1, OUT2, or OUT3.
Output operation
This section explains the judgment output operation.
The arrows in the figure below represent output time.
When "Trig action" is "Cont"
This is the output operation when "Cont" is set for "Trig action".
The figure shows the case when the output time is longer than the sam-
pling period.