Operating the Sensor
38
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
5.3.3
Area
To switch to the Area screen, select the tab in measurement mode,
and then press the “SET” button.
Area screen
Area items
You can use the area settings to configure the following items.
Setting
item
Bank Setting value/
default value
General description
Scaling
Y
Expand or shrink the display range.
*1
Display at 100% size. The whole range will be displayed.
*2
Display at 200% size.
*4
Display at 400% size.
*8
Display at 800% size.
*16
Display at 1600% size.
*32
Display at 3200% size.
H scroll
Y
-
—
Move the display position horizontally. When the display range is at 100% size,
you cannot move the display position.
V scroll
Y
-
—
Move the display position vertically. When the display range is at 100% size,
you cannot move the display position.
Coverage
Y
-
—
Set the range of the area.
Meas func
Y
Select the measurement function of the area. The unit is [mm] unless stated otherwise.
Average
The average of the measured values within the area will be output.
P height
The largest measured value within the area will be output.
B height
The smallest measured value within the area will be output.
Width
The width of the profile that crosses the center of the area will be output.
P pos
The position of the largest measured value within the area will be output.
B pos