Functions
108
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
7.9
Common Settings
7.9.1
Banks
The Profiler 2 stores measurement conditions in “banks.” You can switch
between banks according to the details to measure.
You can use the sensor or communication to switch between banks.
Bank switch
• In/Para
• You can use the sensor screen and input terminals to switch between
banks.
• Comm
• You can use communication to switch between banks. If you use
PRO2-Navigator to switch between banks, this setting will automatically
be switched to “Comm.”
Switching between banks when “Bank switch” is set to “In/Para”
When “Bank switch” is set to “In/Para,” set the input terminals as shown
in the following table in order to switch between banks.
You can use the “Bank” setting of the sensor to switch between banks
when there are terminals that are not assigned to bank 1, 2, or 3.
Bank input 1
Bank input 2
Bank input 3
Bank
OFF
OFF
OFF
1
ON
OFF
OFF
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
ON
5
ON
OFF
ON
6
OFF
ON
ON
7
ON
ON
ON
8
7.9.2
Baud rate
Set the communication speed.
The Profiler 2 communication speed can only be changed from the sensor.
Reference: For details on the communication speed setting,