Serial Communication
122
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
8.5.4
Profile Settings
Function
Set or
acquire
Send
or
reply
Length Command
(hex)
Data string
Parameter
Target
Set
Send
1
4002
000a
a: Measurement target
a
Setting value
a
Setting value
0
Normal
2
Semi-trans
1
Gap
Reply
0
—
Acquire Send
0
4003
—
Reply
1
000a
Alarm limit
Set
Send
1
4008
000a
a: Alarm limit
a
Setting value
a
Setting value
0
Normal
15
Hold operation
1 to
14
Number of
values to hold
Reply
0
—
Acquire Send
0
4009
—
Reply
1
000a
Smoothing
Set
Send
1
4006
000a
a: Smoothing
a
Setting value
a
Setting value
0
1
4
16
1
2
5
32
2
4
6
64
3
8
7
128
Reply
0
—
Acquire Send
0
4007
—
Reply
1
000a
Correct
method
Set
Send
1
4013
0aaa
a: Smoothing
a
Setting value
a
Setting value
0
―
3
↑→
1
→
4
↑←
2
←
5
↑
Reply
0
—
Acquire Send
0
4014
—
Reply
1
0aaa
H correct
Set
Send
1
4015
aaaa
aaaa: Position correction reference height
-14000 to +14000 (×2)
Reply
0
—
Acquire Send
0
4016
—
Reply
1
aaaa
V correct
Set
Send
1
4017
aaaa
aaaa: Height correction reference position
-7500 to +7499 (×2)
Reply
0
—
Acquire Send
0
4018
—
Reply
1
aaaa
Tilt correct
Set
Send
1
4010
0aaa
a: ON/OFF status of tilt correction
a
Setting value
0
OFF
1
ON
Reply
0
—
Acquire Send
0
4011
—
Reply
1
0aaa