Functions
96
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
7.6.2
Measurement functions
Specifys the measurement functions for the areas.
You must configure different settings depending on the measurement
function.
Area
Profile
Average
The average of the measured values within the area are output.
Tips: • Parts where an alarm occurs will not be used in the calculation of the
average value.
• For locations where the measured value is larger or smaller than the
area, the measured values will not be used in the calculation of the
average value.
P height
The largest measured value within the area is output.
Tips: • Parts where an alarm occurs will be ignored.
• Within the range of the area, if there are measured values that are larger
than the area, the peak height value will be the upper limit of the area.
•
The peak is determined by comparing the sizes of the measured values,
so when “Axis dir” is set to “Far+,” the peak will be in relation to the lower
part of the screen.
B height
The smallest measured value within the area is output.
Tips: • Parts where an alarm occurs will be ignored.
• Within the range of the area, if there are measured values that are
smaller than the area, the bottom height value will be the lower limit of
the area.
•
The bottom is determined by comparing the sizes of the measured
values, so when “Axis dir” is set to “Far+,” the bottom will be in relation
to the upper part of the screen.