Functions
90
© SICK AG • Subject to change without notice. • 8017035/ZMO9/2017-06-08
7.5.3
Profile Correction
When the target's position is shifted during measurement, you can correct
the position and height of the area.
With the Profiler 2, you can correct the height, position, and tilt.
Do not use the correction functions when absolute positions are necessary
such as for web guide control.
Tips: • If the correction causes a part of that area to exit the settable range,
measurement will not be possible.
[Reference] Measurement and setting ranges
( ): Measurable area (with the maximum camera area)
[ ]: Settable area
(-8500,25000)
(8500,25000)
(0,0)
(13500,-25000)
(-13500,-25000)
[-15000,28000]
[15000,28000]
[-15000,28000]
[15000,28000]
• You can set one height correction, position correction, and tilt correction
for each bank.
• You can switch between using height correction and position correction
for each area.
• When you are using tilt correction, you cannot set it to ON or OFF for
each area.