8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
109
Functions
7.9.3
Axis dir
Set the direction in which to increase and decrease the height direction
measured value.
Select “Near+” (the measured value will increase toward the side near to
the sensor head) or “Far+” (the measured value will increase toward the
side far from the sensor head). In both situations, the origin is the center
of the measurement range (at 100 mm).
(-8500,-25000)
(8500,-25000)
(0,0)
(13500,25000)
(-13500,25000)
+
+
(-8500,25000)
(8500,25000)
(0,0)
(13500,-25000)
(-13500,-25000)
+
+
Coordinates with “Near+”
Coordinates with “Far+”
Figure: Axis direction and coordinates
Tips: •
In the horizontal directi
on, the measured value always increases
to the right. This cannot be changed with the above setting.
7.9.4
On Timing
Specify the judgment output operation.
• Out range: Output turns on when the measurement result is outside the
range specified by the threshold.
• In range: Output turns on when the measurement result is within the
range specified by the threshold.
7.9.5
Lang/
言語
Change the display language. This setting has no effect on operations.
You can set the display language separately for the sensor and for
PRO2-Navigator.