8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
35
Operating the Sensor
5.3.2
Profile
Use the profile settings to configure the conditions for extracting profiles
from the camera images.
Also, when using the profile position, height, and tilt correction,
set correction conditions.
Profile screen
Height correction
reference position
(purple line)
Position correction
reference height
(blue line)
Tilt correction
reference position
(green line)
Profile items
You can use the profile settings to configure the following items.
Setting
item
Bank Setting value/
default value
General description
Scaling
Y
Expand or shrink the display range.
*1
Display at 100% size. The whole range will be displayed.
*2
Display at 200% size.
*4
Display at 400% size.
*8
Display at 800% size.
*16
Display at 1600% size.
*32
Display at 3200% size.
H scroll
Y
-
—
Move the display position horizontally. When the display range is at 100% size,
you cannot move the display position.
V scroll
Y
Wait...
Move the display position vertically. When the display range is at 100% size,
you cannot move the display position.
Target
Y
Select the measurement target.
Normal
The standard setting to perform measurements.
Gap
Select this setting when the target has large level differences.
The level difference edge precision will be improved.
Semi-trans
Use this setting when you are measuring resin or other semi-transparent objects.