8017035/ZMO9/2017-06-08 • © SICK AG • Subject to change without notice.
75
Functions
7.2.3
Input polar, Inp filter
Input polar
• N.O.:
When input is received through an input terminal,
the input terminal turns on.
• N.C.:
When input is received through an input terminal,
the input terminal turns off.
Inp filter
Set the external input filter time to prevent chattering.
Set this value in steps of 5 μs.
7.2.4
Trig action
The Profiler 2 performs a measurement each time that the trigger
conditions are met. Set the action of this trigger.
Cont
Imaging and measurements are performed continuously while the trigger
is on.
1shot
One measurement is performed when the trigger turns on.
Count
When the trigger has turned on the number of times specified by
“Trig count,” one measurement is performed.
By using an encoder as the trigger, you can perform measurements once
per fixed distance.
Trig count
Specifys the number of triggers to use when “Count” is selected for
“Trig action.”
Trig delay
Sets the delay time between the trigger meeting the camera conditions
and the camera actually taking images.
Set this value in steps of 5 μs.
7.2.5
Offset target
Select the target on which to execute the offset when IN4 is set to “Offset.”
• Indivi:
You can use the input time to select the target on
which to execute the offset.
• All:
The offset is executed on all the outputs.
• OUT1 to OUT3: The offset is executed on the specified output.